자료실 DOWNLOAD ARMOR APR600 RoHS(Restriction of Hazardous Substances Directive) 2019.09.23 Test Report No : 10453380(3) Date : 01-Aug-18 Armor SAS 7 rue de la Pelissiere 44118 LA CHEVROLIERE France The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Name : APR 600 Sample Receiving Date : 20-Jul-18 Testing Period : 20-Jul-18 to 01-Aug-18 Test Requested : In accordance with the RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Result(s) : Sample Description : Black sheet [Test Item(s) / Unit / Method / Results / MDL / RoHS Limit] Cadmium(Cd) / mg/kg / With reference to IEC62321-5:2013. Analysis was performed by ICP/AES / n.d. / 2 / 100 Lead (Pb) / mg/kg / With reference to IEC62321-5:2013. Analysis was performed by ICP/AES / n.d. / 2 / 1000 Mercury (Hg) / mg/kg / With reference to IEC62321-4:2013+A1:2017. Analysis was performed by ICP/AES / n.d. / 2 / 1000 Hexavalent Chromium (Cr(VI)) / mg/kg / With reference to IEC62321-7-2:2017. Analysis was performed by UV/Vis Spectrometry / n.d. / 8 / 1000 Sum of PBBs / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / - / 1000 Monobromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Dibromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tribromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tetrabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Hexabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Pentabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Heptabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Octabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Nonabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Decabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Sum of PBDEs / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / - / 1000 Monobromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Dibromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tribromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tetrabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Pentabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Hexabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Heptabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Octabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Nonabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Decabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - BBP (Benzyl butyl phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DBP (Di-butyl phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DEHP (Di-(2-ethylhexyl) phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DIBP (Di-isobutyl Phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 Note : (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) “-“ = Not regulated (5) * : Exceeds limit (6) Reference information : The limits of Benzyl butyl phthalate (BBP), Di-butyl phthalate (DBP), Di-(2-ethylhexyl) phthalate (DEHP ), Di-isobutyl phthalate (DIBP) as set by G/TBT/N/EU/256 of WTO/TBT. Remarks : Sample received was totally dissolved by preconditioning method. Lab Analyst(s) : AQ, Pheng and ZH APR600_RoHS-Certificate-ARMOR-EN_180801.pdf ARMOR APR5WHITE RoHS(Restriction of Hazardous Substances Directive) 2019.09.23 Test Report No. RN14-12698.013-A Date : 07182014 ARMOR SA 7 RUE DE LAPELISSIERE 44118 LA CHEVROLIERE FRANCE The following sample(s) was/were submitted and identified by/on behalf of the client as : SGS Job No. : RN14-12698.013-A Item / Item No. : THERMAL TRANSFER RIBBON -APR5WHITE Buyer : Mme Melanie BLIN Sample Receiving Date : 06252014 Testing Period : 06252014- 07182014 Test Requested : With reference to RoHS Directive 2011/65/UE, and its amendment directives. Test Method : Please refer to next page(s). Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results are in compliance with the RoHS Directive 2011/65/UE and its subsequent amendments. Test result : ID for sample 1 : THERMAL TRANSFER RIBBON Description for sample 1 : APR5WHITE RoHS Directive 2011/65/UE [Test ltem(s) / Unit / Test Method / Results / MQL / Limit] Cadmium(Cd) / mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by ICP-OES / <MQL / 2 / 100 Lead(Pb) / mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by ICP-OES / <MQL / 2 / 1000 Mercury (Hg) / mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by CV-AFS / <MQL / 0.3 / 1000 Hexavalent Chromium (CrVI) / mg/kg / With reference to IEC 62321:2008, and calculated with the result of total Chromium, and performed by ICP-OES / <MQL / 5 / 1000 Sum of PBBs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 255 / 1000 Monobromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Dibromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Tribromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Tetrabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Pentabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Hexabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - SUM of Heptabromobiphenyl, Octabromobiphenyl and Nonabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 Decabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 / - Sum of PBDEs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 535 / 1000- Monobromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Dibromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 Tribromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Tetrabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 5 / - Pentabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 5 / - Hexabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 5 / - Heptabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / - Octabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 125 / - Nonabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL 125 / - Decabromodiphenyl ether ## / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 250 / - Note : (a) mg/kg = ppm ; 0.1 wt% = 1000ppm (b) n.d.= not detected, than less than le limit of quantification (c) MQL = Method Quantification Limit (d) - = not regulated RoHS_APR5W.pdf ARMOR APR6 RoHS(Restriction of Hazardous Substances Directive) 2019.09.23 Test Report No: 10453380(2) Date : 01-Aug-18 Armor SAS 7 rue de la Pelissiere 44118 LA CHEVROLIERE France The following sample(s) was/were submitted and identified by/on behalf of the client as : Sample Name : APR 6 Sample Receiving Date : 20-Jul-18 Testing Period : 20-Jul-18 to 01-Aug-18 Test Requested : In accordance with the RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Result(s) : Please refer to next page(s). Conclusion : Based on the performed tests on submitted sample(s), the results comply with the RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Result(s) : Sample Description : Black sheet [Test Item(s) / Unit / Method / Results / MDL / RoHS Limit] Cadmium(Cd) / mg/kg / With reference to IEC62321-5:2013. Analysis was performed by ICP/AES / n.d. / 2 / 100 Lead (Pb) / mg/kg / With reference to IEC62321-5:2013. Analysis was performed by ICP/AES / n.d. / 2 / 1000 Mercury (Hg) / mg/kg / With reference to IEC62321-4:2013+A1:2017. Analysis was performed by ICP/AES / n.d. / 2 / 1000 Hexavalent Chromium (Cr(VI)) / mg/kg / With reference to IEC62321-7-2:2017. Analysis was performed by UV/Vis Spectrometry / n.d. / 8 / 1000 Sum of PBBs / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / - / 1000 Monobromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Dibromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tribromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tetrabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Hexabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Pentabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Heptabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Octabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Nonabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Decabromobiphenyl / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Sum of PBDEs / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / - / 1000 Monobromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Dibromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tribromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Tetrabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Pentabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Hexabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Heptabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Octabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Nonabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - Decabromodiphenyl ether / mg/kg / With reference to IEC62321-6:2015. Analysis was performed by GC/MS / n.d. / 5 / - BBP (Benzyl butyl phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DBP (Di-butyl phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DEHP (Di-(2-ethylhexyl) phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 DIBP (Di-isobutyl Phthalate) / mg/kg / With reference to IEC 62321-8:2017. Analysis was performed by GC/MS / n.d. / 50 / 1000 Note : (1) mg/kg = ppm ; 0.1wt% = 1000ppm (2) n.d.= Not Detected (3) MDL = Method Detection Limit (4) “-“ = Not regulated (5) * : Exceeds limit (6) Reference information : The limits of Benzyl butyl phthalate (BBP), Di-butyl phthalate (DBP), Di-(2-ethylhexyl) phthalate (DEHP ), Di-isobutyl phthalate (DIBP) as set by G/TBT/N/EU/256 of WTO/TBT. Remarks : Sample received was totally dissolved by preconditioning method. Lab Analyst(s) : AQ, Pheng and ZH APR6_RoHS-Certificate-ARMOR-EN_180801.pdf ARMOR MSDS(Material Safety Data Sheet) 2019.09.23 SAFETY DATA SHEET Safety Data Sheet (ISO 11014-1) Product name : thermal transfer inked ribbon Date : 19/09/2012 Company : ARMOR S.A. 1 - IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY/UNDERTAKING Identification of the substance or preparation ; Name : thermal transfer inked ribbon Company/undertaking identification Registered company name : ARMOR S.A. Pole de competences industriel TT. Address : ZI La Pelissiere. 44118. La Chevroliere. France. Telephone: 02.51.79.48.76. http://www.armor-group.com Emergency telephone : +33 (0)2 40 38 40 00 Use of the product : For thermal transfer printing. 2 - COMPOSITION/INFORMATION ON INGREDIENTS Hazardous substances present on their own : (present in the preparation at a sufficient concentration to give it the toxicological characteristics it would have in a 100% pure state) This preparation contains no hazardous substance in this category. Other substances representing a hazard : No known substance in this category present. Substances present at a concentration below the minimum danger threshold : No known substance in this category present. Other substances with occupational exposure limits : No known substance in this category present. Other components : None 3 - HAZARDS IDENTIFICATION This product is not classified as flammable. Refer to the recommendations regarding the other products present on the site Other data : None 4 - FIRST AID MEASURES As a general rule, in case of doubt or if symptoms persist, always call a doctor. NEVER induce swallowing in an unconscious person. In the event of exposure by inhalation : none In the event of splashes or contact with eyes : non applicable In the event of splashes or contact with skin : clean with plenty of water and soap In the event of swallowing : Seek medical advise Specific and immediate treatment : none Information for the doctor : transmit this Material Safety Data Sheet 5 - FIRE-FIGHTING MEASURES Not relevant. Suitable extinguishing media : water, foam, CO2 Extinguishing media which must not be used for safety reasons : none Special protective equipment for fire-fighters: - Special exposure hazards arising from the substance or preparation itself, combustion products, resulting gases : CO, CO2 release 6 - ACCIDENTAL RELEASE MEASURES Personal precautions : Consult the safety measures listed under headings 7 and 8. Environmental precautions : Prevent any material from entering drains or waterways. Methods for cleaning up : Clean preferably with a detergent, do not use solvents. 7 - HANDLING AND STORAGE The regulations relating to storage premises apply to workshops where the product is handled. Handling : Avoid inhalation of ink particles in case of flaking. Fire prevention : Prevent access by unauthorised personnel. Recommended equipment and procedures : none Prohibited equipment and procedures : none Storage : Keep away from heat Specific use(s) : none 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Technical measures : personnel shall wear regularly laundered overalls Respiratory protection : none Hand protection : none Eye and face protection : none Skin protection : none Environnemental exposure controls : none 9 - PHYSICAL AND CHEMICAL PROPERTIES General information ; Physical state : inked ribbon Important health, safety and environmental information ; pH of the substance or preparation : not relevant. The pH is impossible to measure or its value is not relevant. Flash point interval : not relevant. Vapour pressure : not relevant. Density : >1 Water solubility : Insoluble. Other information ; melting point/melting range : not specified. 10 - STABILITY AND REACTIVITY The product is stable at the handling and storage conditions recommended per § 7 of the safety data sheet, Conditions to avoid : none Materials to avoid : none Hazardous decomposition products : none 11 - TOXICOLOGICAL INFORMATION The preparation contains no substance classified as hazardous per directive 67/548/EEC. No data is available regarding the preparation itself. In the event of exposure by inhalation : No data available In the event of swallowing : non applicable In the event of splashes or contact with skin : none In the event of splashes or contact with eyes : none Classification on the basis of toxicological properties ; Other data : none 12 - ECOLOGICAL INFORMATION No ecological data on the product itself is available. 13 - DISPOSAL CONSIDERATIONS Do not pour into drains or waterways. Waste : Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company. Do not contaminate the ground or water with waste, do not dispose of waste into the environment. Soiled packaging : Give to a certified disposal contractor. Local arrangements : Codes of wastes (Decision 2001/573/EC, Directive 2006/12/EEC, Directive 94/31/EEC on hazardous waste) : 07 02 13 waste plastic 14 - TRANSPORT INFORMATION Exempt from transport classification and labelling. 15 - REGULATORY INFORMATION This product is not classified as flammable. Particular provisions : none 16 - OTHER INFORMATION Since the user's working conditions are not known by us, the information supplied on this safety data sheet is based on our current level of knowledge and on national and community regulations. The product must not be used for any purposes other than those specified under heading 1 without first obtaining written handling instructions. It is at all times the responsibility of the user to take all necessary measures to comply with legal requirements and local regulations. The information given on this safety data sheet must be regarded as a description of the safety requirements relating to our product and not a guarantee of its properties. MSDS_GB.pdf 처음«1234 전체 제목 내용 작성자 검색 Add. 서울시 금천구 가산디지털2로 101 한라원앤원타워 A동 1502호 Tel. 02. 2038. 0018 Fax. 02. 2038. 0058 Email. hion@hionit.com