Test Report

No. RN14-12698.020-A
Date : 07182014

ARMOR SA
7 RUE DE LA PELISSIERE 44118 LA CHEVROLIERE FRANCE

The following sample(s) was/were submitted and identified by/on behalf of the client as :
SGS Job No. : RN14-12698.020-A
Item I Item No. : THERMAL TRANSFER RIBBON -AWR470
Buyer : Mme Melanie BLIN
Sample Receiving Date : 06252014
Testing Period : 06252014- 07182014

Test Requested : With reference to RoHS Directive 2011/65/UE, and its amendment directives.
Test Method : Please refer to next page(s).
Test Result(s) : Please refer to next page(s).
Conclusion : Based on the performed tests on submitted sample(s), the results are in compliance with the RoHS Directive 2011/65/UE and its subsequent amendments.

Test result :
ID for sample 1 : THERMAL TRANSFER RIBBON
Description for sample 1 : AWR470

RoHS Directive 2011/65/UE

[Test ltem(s) / Unit / Test Method / Results / MQL / Limit]
Cadmium(Cd) / mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by ICP-OES / <MQL / 2 / 100
Lead (Pb) mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by ICP-OES / <MQL / 2 / 1000
Mercury (Hg) / mg/kg / IEC 62321:2008 (Ed. 12/2008) with modified digestion procedure, and performed by CV-AFS / <MQL / 0.3 / 1000
Hexavalent Chromium (CrVI) / mg/kg / With reference to IEC 62321:2008, and calculated with the result of total Chromium, and performed by ICP-OES / <MQL / 2 / 1000
Sum of PBBs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 255 / 1000
Monobromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Dibromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tribromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tetrabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Pentabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Hexabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
SUM of Heptabromobiphenyl, Octabromobiphenyl and Nonabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125
Decabromobiphenyl / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 / -
Sum of PBDEs / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 535 / 1000-
Monobromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Dibromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5
Tribromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Tetrabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Pentabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Hexabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Heptabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 5 / -
Octabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 / -
Nonabromodiphenyl ether / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 125 / -
Decabromodiphenyl ether ## / mg/kg / IEC 62321:2008 with modified extraction procedure, and performed by GC-MS / <MQL / 250 / -

Note :
(a) mg/kg = ppm ; 0.1 wt% = 1000ppm
(b) n.d. = not detected, than less than le limit of quantification
(c) MQL = Method Quantification Limit
(d) - = not regulated